Protector contra descargas para PTP600
Review: 5 -
Rated 5/5 based on 11 customer reviews
"Excelentes productos" by , written onJun 4, 2021
Los productos siempre en tiempo y forma.

Protector contra descargas para PTP600

Disponible: En Stock
$ 7,280.71 MXN
Image

The Cambium Networks PTP 650 Wireless Broadband solutions are ruggedized to operate in the toughest environments. Lightning strikes are the most typical cause of system outages or failures of mast-mounted equipment, especially when mounted as high as 300m. Therefore, lightning protection is critical to minimize the potential for damage.

Cambium Networks strongly recommends that all PTP 650 installations should be
deployed with the PTP-LPU. Network operators should always follow best-practices for grounding and lightning protection. Doing so will minimize network outages and reduce the associated costs of tower climbs and equipment repair/replacement.

Compatible with all bands

Transfer rate: 1000 Base T
Connectors: RJ 45
Protection mode: Line-to-line and line-to-ground
Response time: 5 nanoseconds
Mounting: Pole mount 1-3” (25-75 mm), or wall mount
Metal enclosure Projected 10-year operational life
Dimensions (including glands): 6.3” Length (16 cm), 4” (10 cm) Width, 3.5” (9 cm) Height
Weight: 1.5 lbs (700 g)
Wind loading: 150 mph (242 kph)
Operating temperature: -40° F (-40° C) to +140° F (+60° C)
Humidity: 100% condensing
Tested to IEEE / ANSI C62.41 10/1000 long wave: 120 amp peak, peak power 14,000 watts
Environmental protection: IP65 / NEMA-3R

The Cambium Networks PTP 650 Wireless Broadband solutions are ruggedized to operate in the toughest environments. Lightning strikes are the most typical cause of system outages or failures of mast-mounted equipment, especially when mounted as high as 300m. Therefore, lightning protection is critical to minimize the potential for damage.

Cambium Networks strongly recommends that all PTP 650 installations should be
deployed with the PTP-LPU. Network operators should always follow best-practices for grounding and lightning protection. Doing so will minimize network outages and reduce the associated costs of tower climbs and equipment repair/replacement.

Compatible with all bands

Transfer rate: 1000 Base T
Connectors: RJ 45
Protection mode: Line-to-line and line-to-ground
Response time: 5 nanoseconds
Mounting: Pole mount 1-3” (25-75 mm), or wall mount
Metal enclosure Projected 10-year operational life
Dimensions (including glands): 6.3” Length (16 cm), 4” (10 cm) Width, 3.5” (9 cm) Height
Weight: 1.5 lbs (700 g)
Wind loading: 150 mph (242 kph)
Operating temperature: -40° F (-40° C) to +140° F (+60° C)
Humidity: 100% condensing
Tested to IEEE / ANSI C62.41 10/1000 long wave: 120 amp peak, peak power 14,000 watts